Genemco Sells Used Shell and Tube Heat Exchangers from Refrigeration Valves and Systems Corp., Dunham-Bush, Vilter, Bohn, Enerquip, California Hydronics 
 High Quality Used Shell and Tube Heat Exchangers 

Click On Picture

 Unused 2010 Chil-Con Stainless Steel Shell & Tube Heat Exchanger and Surge Drum

Unused 2010 Chil-Con Stainless Steel Shell & Tube Heat Exchanger and Surge Drum
Mfg: Chil-Con Model: FA-24204-410
Stock No: HGPM055.75 Serial No: C300531A-1
Unused 2010 Chil-Con Stainless Steel Shell & Tube Heat Exchanger and Surge Drum. Model(s): FA-24204-410 and RA-30180-509. Designed to chill 663 gpm of heat transfer fluid (Dowtherm J®) input at -57F, output at -67F, using 2263 pounds per hour of ammonia R717 at 22" vacuum -72F. Capacity: 1,200,000 BTU/hr. Respective shell and tube side DWP: 250 and 150 PSIG. Shell and tube side DWT rated at 250 psi at -80°F to 200º F. Overall dimensions: 20 ft. L x 3 ft. 6 in. W x 8 ft. H.(ACN875).

Click here for more information (167.0 KB)
Click here for drawing (47.2 KB)

Click On Picture

Stainless Steel Shell and Tube Heat Exchanger - 565 sq. ft.

SOLD Stainless Steel Shell and Tube Heat Exchanger - 565 sq. ft.
Mfg: Not Specified Model:
Stock No: OI272. Serial No:
Stainless Steel Shell and Tube Heat Exchanger. (108) 2 in. dia. x 10 ft. L stainless steel multi-tubes. Heat transfer surface area: approx. 565 sq. ft. Volume: 175 gallon. Inlets: (1) 1-1/2 in. dia. S-line fitting (sprayball), (1) 12 in. dia. flanged port (media), (1) 20 in. dia. flange port (product). Outlets: (1) 2 in. dia. FNPT (media), (1) 2-1/2 in. dia. FNPT (media), (1) 8 in. dia. flanged port (product). Overall dimensions: 4 ft. 8 in. L x 4 ft. W x 15 ft. H.

SOLD

Click here for more information (319.6 KB)

Click On Picture

Stainless Steel Shell and Tube Heat Exchanger - 570.86 sq. ft.

SOLD Stainless Steel Shell and Tube Heat Exchanger - 570.86 sq. ft.
Mfg: Not Specified Model:
Stock No: 35.343a Serial No:
Stainless Steel Shell and Tube Heat Exchanger. Tube material: 316 stainless steel. Number of passes: 1. Number of tubes: 110. Tube dimensions: 2 in. dia. x 9 ft. 11 in. L. Heat transfer surface area: approx. 570.86 sq. ft. Tube volume: 175 gal. Inlets: (1) 8 in. dia. port, (1) 1 in. dia. port, (1) 3 in. dia. S-Line. Outlets: (1) 3-1/2 in. dia. port, (1) 1 in. dia. port, 16 in. L x 16 in. W manway. Overall dimensions: 4 ft. 11-1/2 in. L x 3 ft. 11 in. W x 13 ft. 9 in. H.

SOLD

Click here for more information (196.5 KB)

Click On Picture

1998 Vilter Shell and Tube 18 ft. Ammonia Heat Exchanger - 712 sq. ft.

SOLD 1998 Vilter Shell and Tube 18 ft. Ammonia Heat Exchanger - 712 sq. ft.
Mfg: Vilter Model:
Stock No: HDCD367.7 Serial No: H73946-1
1998 Vilter Shell and Tube 18 ft. Ammonia Heat Exchanger. S/N: H73946-1. Nat'l Bd: 41337. Number of passes: 4. Number of tubes: 121. Tube material: SA-124 carbon steel. Tube dimensions: 1-1/4 in. dia. x 18 ft. Heat transfer surface area: approx. 712 sq. ft. Shell side MAWP @ 400 °F: 300 psig. Shell side MDMT @ 300 psig: -20 °F. Tube side MAWP @ 200 °F: 75 psig. Tube side MDMT @ 75 psig: -20 °F. Heat exchanger is equipped with Hansen pressure relief valves. Inlets: (1) 3-1/2 in. dia. pipe (media), (1) 4 in. dia. pipe (product) with an 8-1/2 in. dia. flange and (8) 3/4 in. dia. attachment holes at a center-to-center distance of 6-1/2 in. Outlets: (1) 2 in. dia. Pipe (media), (1) 4 in. dia. pipe (product) with an 8-1/2 in. dia. flange and (8) 3/4 in. dia. attachment holes at a center-to-center distance of 6-1/2 in. Shell: 20 in. dia. x 18 ft. L. Overall dimensions: 19 ft. L x 28 in. W x 70 in. H. (ACN250)

SOLD

Click here for more information (751.5 KB)
Click here for Schematics Drawings (62.0 KB)

Click On Picture

1996 Refrigeration Valves and Systems Corp. Shell and Tube Heat Exchanger  - 80 Tons - 530 sq. ft.

SOLD 1996 Refrigeration Valves and Systems Corp. Shell and Tube Heat Exchanger - 80 Tons - 530 sq. ft.
Mfg: Refrigeration Valves and Systems Corp. Model: Precision
Stock No: HDCS244.9 Serial No: 96407 and 96408
1996 Refrigeration Valves and Systems Corp. Shell and Tube Heat Exchanger. Model: Precision. S/N's: 96407 and 96408. Nat'l Bd: 9028 and 9029. Capacity: 960,000 btu/hr = 80 tons of refrigeration. Tube material: SA214-ERW. Number of passes: 4. Number of tubes: 180. Tube dimensions: 3/4 in. dia. x 15 ft. L. Heat transfer surface area: approx. 530 sq. ft. Tube volume: 60 gal. Shell side MAWP: 250 psi @ 200 °F. Shell side MDMT: 250 psi @ -20 °F. Tube side MAWP: 100 psi @ 200 °F. Tube side MDMT: 250 psi @ -20 °F. Surge Tank- 85 Gallon, inside straight-wall dimensions: 1 ft. 2 in. dia. x 11 ft. L. Inlets: (2) 1-1/4 in. dia. liquid refrigerant feed ports, (1) 4 in. dia. flanged liquid port. Outlets: (1) 3/4 in. dia. liquid drain port, (1) 3 in. dia. refrigerant suction port, (1) 4 in. dia. flanged liquid port. Overall dimensions: 16 ft. 4 in. L x 5 ft. W x 8 ft. 4 in. H. (ACN237)

SOLD

Click here for more information (447.2 KB)
Click here for drawing (676.0 KB)

Click Here if you don't see what you're looking for in our online catalog.


 Genemco Sells Used Shell and Tube Heat Exchangers at Competitive Prices